Comments on: Repeatability of Orbscan III for anterior segment parameters in normal eyes
نویسندگان
چکیده
منابع مشابه
Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimp g Analyzer
Address for Correspondence: Zeynep Altıparmak MD, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey Tel.: +90 532 307 91 40 E-mail: [email protected] Received: 02.10.2014 Accepted: 15.02.2015 This article is also published in Turkish under doi:10.4274/tjo.16768 pages 2015;45:243-248 Objectives: To assess the repeatability and reproducibility of anterior segment measurements includi...
متن کاملRepeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer
OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal high...
متن کاملComparative Analysis of Anterior Segment Parameters in Normal and Keratoconus Eyes Generated by Scheimpflug Tomography
Purpose. To assess and compare the anterior and posterior corneal surface parameters, keratoconus indices, thickness profile data, and data from enhanced elevation maps of keratoconic and normal corneas with the Pentacam Scheimpflug corneal tomography and to determine the sensitivity and specificity of these parameters in discriminating keratoconus from normal eyes. Methods. The study included ...
متن کاملValidity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan.
PURPOSE The purpose of this study was to determine the validity and repeatability of anterior chamber depth (ACD) measurements obtained with a novel rotating Scheimpflug camera (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) to scanning slit topography (Orbscan; Bausch & Lomb, Rochester, NY). METHODS ACD in 60 healthy eyes was measured twice by two independent observers with each modali...
متن کاملEvaluation of Anterior Segment Parameters in Obesity
PURPOSE To investigate anterior segment parameters in obese patients in comparison to healthy individuals. METHODS Thirty-four obese subjects and 34 age-sex-matched healthy subjects were enrolled in this prospective cross-sectional study. Ophthalmological examinations including intraocular pressure (IOP), central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Ophthalmology
سال: 2021
ISSN: 0301-4738
DOI: 10.4103/ijo.ijo_144_21