Combining Isotope Dilution and Standard Addition—Elemental Analysis in Complex Samples

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Existing and emerging technologies for measuring stable isotope labelled retinol in biological samples: isotope dilution analysis of body retinol stores.

This paper discusses some of the recent improvements in instrumentation used for stable isotope tracer measurements in the context of measuring retinol stores, in vivo. Tracer costs, together with concerns that larger tracer doses may perturb the parameter under study, demand that ever more sensitive mass spectrometric techniques are developed. GCMS is the most widely used technique. It has hig...

متن کامل

Application of isotopically labeled methylmercury for isotope dilution analysis of biological samples using gas chromatography/ICPMS.

An isotope dilution (ID) procedure for the determination of methylmercury (MMHg) in biological samples using an inductively coupled plasma mass spectrometer as detector after the capillary gas chromatographic separation (CGC/ICPMS) has been developed. For the first time, open-focused-microwave pretreatment has been used in conjunction with ID. Optimum conditions for the measurement of isotope r...

متن کامل

Isotope Dilution Residue Function

We analyzed the isotope dilution residue function from a single cardiac chamber for an arbitrary inlet distribution of tracer and arbitrary mixing within the chamber, and established a general relationship between cardiac output and the chamber residue function. In our experiments, we made simultaneous temperature measurements in three left ventricular chamber subregions of the dog subjected to...

متن کامل

Stable Isotope Dilution Assay Mass Spectrometry in Flavour Research: Internal Standard and Calibration Issues

Mass spectrometry is widely used in flavour research to quantify compounds by using isotopically labelled internal standards. However, equimolar amounts of different molecules do not give equal instrumental responses. Therefore, calibration of the mass spectrometer is needed prior to any sample quantification. If the mass of the internal standard differs from that of the analyte by more than 3 ...

متن کامل

Improved measurement of iodine in food samples using inductively coupled plasma isotope dilution mass spectrometry.

A new ICP-MS method for the determination of iodine in food samples is presented. The method makes use of a new miniature cyclonic spray chamber and a concentric glass nebulizer that is designed for low sample uptakes and is operated in a self-aspirating mode. As a consequence the wash-out was accelerated over conventional systems. This configuration allows the direct determination of iodine in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Molecules

سال: 2021

ISSN: 1420-3049

DOI: 10.3390/molecules26092649