Combined Tc-99m sesta MIBI scintigraphy and Ultrasonography in preoperative detection and localization of parathyroid adenoma
نویسندگان
چکیده
منابع مشابه
Localization of ectopic parathyroid adenoma with Tc-99m-MIBI [Persian]
Ectopic paratliyroid adenoma might create a clinical dilemma in patients with hypercalcemia. Radioisotopic scan is a sensitive and noninvasive method which can be useful in these patients. In this report a case of ectopic parathyroid adenoma is presented and the usefulness of TC-99m-MIBI scintigraphy as compared with other modalities is discussed.
متن کاملlocalization of ectopic parathyroid adenoma with tc-99m-mibi [persian]
ectopic paratliyroid adenoma might create a clinical dilemma in patients with hypercalcemia. radioisotopic scan is a sensitive and noninvasive method which can be useful in these patients. in this report a case of ectopic parathyroid adenoma is presented and the usefulness of tc-99m-mibi scintigraphy as compared with other modalities is discussed.
متن کاملLocalization of An Etopic Parathyroid Adenoma by Technetium- 99m-MIBI Scintigraphy and An Intraoperative Gamma Probe
Received 8/30/2000; accepted 9/5/2000. For correspondence or reprints contact: Chia-Hung Kao, M.D., Department of Nuclear Medicine, Taichung Veterans General Hospital, 160, Sec. 3, Taichung Harbor Road, Taichung 407, Taiwan, R.O.C. Tel: (886)4-23741349, FAX: (886)4-23741348, E-Mail: [email protected] Tc-MIBI scanning has become the preferred mode to detect and localize parathyroid adenom...
متن کاملThyroid Pyramidal Lobe Mimicking Parathyroid Adenoma in Tc-MIBI Parathyroid Scintigraphy
Received 11/22/2006; revised 2/14/2007; accepted 2/26/2007. For correspondence or reprints contact: Pei-Wen Wang, M.D., Department of Nuclear Medicine, Chang Gung Memorial Hospital-Kaohsiung Medical Center. 123 Ta-Pei Road, Niao-Sung, Kaohsiung 833, Taiwan, ROC. Tel: (886)7-7317123 ext. 2627, Fax: (886)7-7317123 ext. 2631, E-mail: [email protected] The Tc-MIBI parathyroid imaging is useful for...
متن کاملParathyroid glands: combination of sestamibi-(99m)Tc scintigraphy and ultrasonography for demonstration of hyperplasic parathyroid glands.
OBJECTIVE To determine the frequency of the types of parathyroid gland hyperplasia and the sensitivity of sestamibi-(99m)Tc (MIBI) scintigraphy and ultrasonography (US) of patients with secondary hyperparathyroidism (SHPT) due to chronic renal failure. MATERIAL AND METHODS We studied 43 patients with SHPT (26 females and 17 males with age range of 27-75 years). Blood tests were performed to d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Egyptian Journal of Radiology and Nuclear Medicine
سال: 2015
ISSN: 0378-603X
DOI: 10.1016/j.ejrnm.2015.07.006