Combined abutment screw and implant platform fracture of screw‐retained bridge
نویسندگان
چکیده
Abstract Dental implant failure can be due to biological or technical problems. The incidence of body fracture is rare with less than 1.5% the reported cases. design, manufacturing defect, non‐passive fit prosthetic framework, and physiologic and/or biomechanical overload. We report a event combined abutment screws neck fixtures two implants restored fixed bridge in mandibular left first second molar region. dilemma identifying this situation stepwise clinical events described detail. platform was diagnosed help cone beam computed tomography addition examination. severe mesial cantilever lingual inclination were found possible causative factors. Both removed trephine burs, patient recalled after 3 months for re‐evaluation.
منابع مشابه
Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System
The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill ...
متن کاملCorrelation between microleakage and screw loosening at implant-abutment connection
PURPOSE This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to...
متن کاملNew abutment for a screw-retained, implant-supported crown.
The 1-piece, implant-supported abutment and crown, colloquially described as the UCLA abutment, commonly is used to fabricate single, screw-retained crowns. This abutment was designed to allow attachment of the crown directly to the implant and requires a waxing and casting procedure by a laboratory technician. A new prefabricated abutment has been developed that uses a similar approach but doe...
متن کاملAbutment screw loosening in single-implant restorations: a systematic review.
PURPOSE The purpose of this study was to systematically review clinical studies on the incidence of abutment screw loosening in single-implant restorations with different implant-abutment connection geometries. MATERIALS AND METHODS The literature search was conducted using several electronic databases. Specific terms were used for the database search, which spanned the years 1990 to 2006. Th...
متن کاملEffect of Casting Procedure on Screw Loosening of Ucla Abutment in Two Implant-abutment Connection Systems
Since Bra�nemark et al published the results of a 10-year study on osseointegration in 1977, dental implants have increasingly been used to replace missing teeth. The use of osseointegrated implants had become a successful procedure for the treatment of complete, partial edentulism, and single-tooth replacements in both the anterior and posterior regions of the mouth. Although improvements in m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Oral Surgery
سال: 2023
ISSN: ['1752-2471', '1752-248X']
DOI: https://doi.org/10.1111/ors.12836