Cold test of cylindrical open resonator for 42 GHz, 200 kW gyrotron

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photonic-band-gap resonator gyrotron.

We report the design and experimental demonstration of a gyrotron oscillator using a photonic-band-gap (PBG) structure to eliminate mode competition in a highly overmoded resonator. The PBG cavity supports a TE(041)-like mode at 140 GHz and is designed to have no competing modes over a minimum frequency range delta omega/omega of 30% about the design mode. Experimental operation of a PBG gyrotr...

متن کامل

A novel wideband 140 GHz gyrotron amplifier

The theory, design and experimental results of a wideband 140 GHz, 1 kW pulsed gyro-traveling wave amplifier are presented. The gyro-TWA operates in the HE(0,6) mode of a novel cylindrical confocal waveguide using a gyrating electron beam. The electromagnetic theory, interaction theory, design processes and experimental procedures have been described in detail. The experiment has produced over ...

متن کامل

Electromagnetic Analysis and Cold Test of a Distributed Window for a High Power Gyrotron

A novel distributed window for output radiation from a high power 110 GHz gyrotron is made of thin slats of sapphire interleaved and brazed to hollow metal vanes. We report the results of electromagnetic theory and cold test of this distributed window. We calculate the frequency dependence of the reflectivity of a Gaussian beam from the window. The theory indicates a significant frequency shift...

متن کامل

A 250 GHz gyrotron with a 3 GHz tuning bandwidth for dynamic nuclear polarization.

We describe the design and implementation of a novel tunable 250 GHz gyrotron oscillator with >10 W output power over most of a 3 GHz band and >35 W peak power. The tuning bandwidth and power are sufficient to generate a >1 MHz nutation frequency across the entire nitroxide EPR lineshape for cross effect DNP, as well as to excite solid effect transitions utilizing other radicals, without the ne...

متن کامل

Pulling and Bandwidth Measurements of a 140 GHz Pulsed Gyrotron

Accurate measurements of the emission frequency and bandwidth of a pulsed 140 GHz gyrotron have been made using a harmonic mixer system. This system has been used to measure the bandwidth of individual, 1 Asec pulses of the gyrotron, to determine the dependence of the operating frequency on the cathode voltage and resonator magnetic field, to detect and identify second harmonic radiation, and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sadhana

سال: 2013

ISSN: 0256-2499,0973-7677

DOI: 10.1007/s12046-013-0156-y