CoCrMo cellular structures made by Electron Beam Melting studied by local tomography and finite element modelling

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Open-Cellular Co-Base and Ni-Base Superalloys Fabricated by Electron Beam Melting

Reticulated mesh samples of Co-29Cr-6Mo alloy and Ni-21Cr-9Mo-4Nb alloy (625) and stochastic foam samples of Co-29Cr-6Mo alloy fabricated by electron beam melting were characterized by optical metallography, and the dynamic stiffness (Young's modulus) was measured by resonant frequency analysis. The relative stiffness (E/Es) versus relative density (ρ/ρs) plotted on a log-log basis resulted in ...

متن کامل

A Simple Finite Element Procedure for Free Vibration and Buckling Analysis of Cracked Beam-Like Structures

In this study, a novel and very simple finite element procedure is presented for free vibration and buckling analysis of slim beam-like structures damaged by edge cracks. A cracked region of a beam is modeled using a very short element with reduced second moment of area (I). For computing reduced I in a cracked region, the elementary theory of bending of beams and local flexibility approach are...

متن کامل

Investigation of Tantalum Recycling by Electron Beam Melting

Investigations are carried out and obtained experimental and theoretical data for tantalum scrap recycling by electron beam melting (EBM) is presented in this paper. Different thermal treatment process conditions are realized and results are discussed. A chemical analysis is performed and refining mechanisms for electron beam (EB) refining of Ta are discussed. For the performed experiments the ...

متن کامل

Detection of local lung air content by electrical impedance tomography compared with electron beam CT.

The aim of the study was to validate the ability of electrical impedance tomography (EIT) to detect local changes in air content, resulting from modified ventilator settings, by comparing EIT findings with electron beam computed tomography (EBCT) scans obtained under identical steady-state conditions. The experiments were carried out on six anesthetized supine pigs ventilated with five tidal vo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Materials Characterization

سال: 2016

ISSN: 1044-5803

DOI: 10.1016/j.matchar.2016.04.006