Cochlear implant phantom for evaluating computed tomography acquisition parameters
نویسندگان
چکیده
منابع مشابه
The Cochlear Implant
The studies on cochlear implants have been conducted in the United States, Austria, Brasil, France, Finland, and some other countries. Up to now, this technique does not seem to have a wide spread application. Indeed it can only apply cases of deafness still presenting sufficient neural remnants to transmit the message. Moreover, the patient must be totally deaf( quasi complete loss of har cel...
متن کاملNew method of evaluating edge-preserving adaptive filters for computed tomography (CT): digital phantom method.
To evaluate the characteristics of edge-preserving adaptive filters for selectively eliminating noise without affecting resolution in low-dose scanning, we have developed a digital phantom image and evaluated noise statistical values, noise characteristics, and resolution characteristics. The results confirmed that edge-preserving adaptive filters function as smoothing filters in low-contrast r...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملDevelopment of Computed Tomography Head and Body Phantom for Organ Dosimetry
Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...
متن کاملComputed tomography of single-channel cochlear implants.
Computed tomographic (CT) examinations were performed in seven patients after cochlear implant surgery. Preimplantation CT demonstrated the petrous anatomy well and revealed an abnormality in one case. Postimplantation CT adequately assessed electrode position in all cases. Malposition of the active electrode was identified in one patient. Electrode position was correlated with postimplantation...