Cobas Mira S Endpoint Enzymatic Assay for Plasma Formate
نویسندگان
چکیده
منابع مشابه
Laboratory evaluation of the COBAS MIRA S random access analyser
The random access analyser COBAS MIRA S (Roche Diagnostics) was evaluated for two months. The instrument is a computer-controlled discrete analyser which can be run in a combination profile and single test mode. This instrument has special features, including an automatic cuvette segment changer, a reagent rack cooling system, an external keyboard and monitor, as well as a bar-code facility for...
متن کاملAutomated enzymatic assay for plasma ammonia.
An enzymatic method for determining plasma ammonia with the Du Pont Automatic Clinical Analyzer (aca) is described. The assay requires a sample volume of 500 muL for a kinetic ammonia measurement. The reaction is initiated with glutamate dehydrogenase and the rate of depletion of NADPH is monitored with two measurements, 17 s apart, at 340 nm. Reaction conditions have been optimized for maximum...
متن کاملHomogeneous, nonradioactive, enzymatic assay for plasma pyridoxal 5-phosphate.
BACKGROUND Pyridoxal 5'-phosphate (PLP) is the biologically active form of vitamin B(6). Clinical studies suggest that low PLP concentrations are an independent risk factor for cardiovascular and other diseases. However, PLP concentrations are not routinely diagnosed because of the lack of a homogeneous, nonradioactive assay. We describe a homogeneous, nonradioactive, enzymatic PLP assay that u...
متن کاملEnzymatic assay for spermidine.
The polyamine spermidine (NH,(CH&NH(CH&NH,) is widespread in nature. It is present in mammalian tissues (1, 2), plants (3), bacteria (47), ribosomes (6, 8), and bacteriophages (9-11). There are various methods for its identification, including steam distillation (12)) paper chromatography (13-18)) paper electrophoresis (14, 16, 17, 19), ion exchange chromatography (2, 5), gas chromatography (31...
متن کاملEnzymatic cycling assay for phenylpyruvate.
Enzymatic cycling assays for the determination of L-phenylalanine and phenylpyruvate in deproteinized tissue extracts are described. Assay 1 couples glutamine transaminase K with L-phenylalanine dehydrogenase. Assay 2 combines phenylalanine dehydrogenase, L-amino acid oxidase, and catalase. In both assays, tyrosine and some other amino acids (or their alpha-keto acid analogs) can replace phenyl...