Closed Suction Drainage Is Not Associated with Faster Recovery after Total Knee Arthroplasty
نویسندگان
چکیده
منابع مشابه
[Closed suction drainage or non-drainage for total knee arthroplasty: a meta-analysis].
OBJECTIVES To investigate the different effects of closed suction drainage and non-drainage for total knee arthroplasty(TKA) and to provide reference information for the choice of clinical treatment. METHODS Randomized controlled trials (RCTs) of closed suction drainage versus non-drainage for TKA were collected from the Cochrane Library, PubMed, EMBase, Springer, CBM, CNKI, VIP and WANFANG d...
متن کاملComparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis
BACKGROUND Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT dra...
متن کاملComparison Between Closed Suction Drainage and No Drainage Following Total Knee Arthroplasty in a Tertiary Care Setting in Pakistan
BACKGROUND Total knee arthroplasty is associated with hematoma formation and extensive blood loss up to 1.5 liters. The placement of a closed suction drain to control this complication is controversial. The purpose of this study is to determine the efficacy between total knee arthroplasty without a drain and with a closed suction drain. Methods: A retrospective cohort study was conducted betwe...
متن کاملSuction dressings in total knee arthroplasty--an alternative to deep suction drainage.
A new technique is described for dressing of surgical wounds in total knee arthroplasty that is a combination of a semi-permeable dressing and suction drainage. This technique has been used in 100 consecutive cases and drainage was collected in 92. The average volume was 198 ml (range 30 to 850 ml). There was no superficial or deep sepsis. Haematoma formation causing moderate soft tissue tensio...
متن کاملUse of closed suction drain after primary total knee arthroplasty – an overrated practice
PURPOSE The age-old practice of closed suction drain following orthopedic procedures has been challenged since past few decades. Our aim was to assess the effectiveness of closed suction drain after total knee arthroplasty. MATERIALS AND METHODS One hundred twenty patients (135 knees) with primary Total Knee Arthroplasty were divided into a study group (no drain) and a control group (drain us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopaedic Surgery
سال: 2016
ISSN: 1757-7853
DOI: 10.1111/os.12247