Closed-loop optogenetic intervention in mice

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed-Loop and Activity-Guided Optogenetic Control

Advances in optical manipulation and observation of neural activity have set the stage for widespread implementation of closed-loop and activity-guided optical control of neural circuit dynamics. Closing the loop optogenetically (i.e., basing optogenetic stimulation on simultaneously observed dynamics in a principled way) is a powerful strategy for causal investigation of neural circuitry. In p...

متن کامل

Design strategies for dynamic closed-loop optogenetic neurocontrol in vivo.

OBJECTIVE Controlling neural activity enables the possibility of manipulating sensory perception, cognitive processes, and body movement, in addition to providing a powerful framework for functionally disentangling the neural circuits that underlie these complex phenomena. Over the last decade, optogenetic stimulation has become an increasingly important and powerful tool for understanding neur...

متن کامل

Controlling the oscillation phase through precisely timed closed-loop optogenetic stimulation: a computational study

Dynamic oscillatory coherence is believed to play a central role in flexible communication between brain circuits. To test this communication-through-coherence hypothesis, experimental protocols that allow a reliable control of phase-relations between neuronal populations are needed. In this modeling study, we explore the potential of closed-loop optogenetic stimulation for the control of funct...

متن کامل

Closed-loop optogenetic control of thalamus as a tool for interrupting seizures after cortical injury

Despite the high prevalence of stroke and epilepsy, both major sources of disability1–4, the underlying cellular and circuit mechanisms leading from stroke to epilepsy remain unknown, and injury-induced epilepsies often do not respond to existing treatments3,5. Identification of the neural circuits involved in injury-induced epilepsy is necessary to pinpoint the exact nature of the causally imp...

متن کامل

Distance protection closed-loop testing using RTDS

This paper presents a distance protection test procedure by applying the Real-Time Digital Simulator (RTDS) of a power system. RTDS is a tool to design, develop, and test power-system protection. The RTDS enables real-time computation of electromagnetic phenomena with a calculation time step of even 50μs. The hardware allows the import and export of many signals from the simulator to an ext...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nature Protocols

سال: 2013

ISSN: 1754-2189,1750-2799

DOI: 10.1038/nprot.2013.080