Title of thesis: CLOSED-LOOP FLUID RESUSCITATION: INSILICO STUDY Jonathan Cary Lucas V, Master of Science, 2015 Thesis directed by: Dr. Jin-Oh Hahn Department of Mechanical Engineering This thesis validates a control-oriented model of human circulatory dynamics associated with hemorrhage and fluid resuscitation, uses this model to design a series of closed-loop controllers for fluid resuscitati...
متن کاملLimited fluid volume resuscitation.
Volume replacement therapy is crucial to the treatment of hypovolemic shock. In patients with certain conditions, limiting the volume of fluid administered has many potential therapeutic benefits and technical advantages. Hypertonic saline and colloids have characteristics that allow effective treatment of hypovolemic shock using relatively smaller volumes than would be required for isotonic cr...
متن کاملStrategies for Small Volume Resuscitation Hyperosmotic-Hyperoncotic Solutions, Hemoglobin Based Oxygen Carriers and Closed-Loop Resuscitation
Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loo...
متن کاملSensor selection via closed-loop control objectives
The ability to stabilize a system and achieve performance objectives using active feedback control is highly dependent on the location, quality, type, and number of control actuators and sensors. One role of a control engineer is to interact with the system designer to locate, size, and determine the quality of actuators and sensors required for effective control. This paper addresses one of th...
متن کاملClosed-loop control of fluid therapy for treatment of hypovolemia.
Closed-loop algorithms and resuscitation systems are being developed to control IV infusion rate during early resuscitation of hypovolemia. Although several different physiologic variables have been suggested as an endpoint to guide fluid therapy, blood pressure remains the most used variable for the initial assessment of hemorrhagic shock and the treatment response to volume loading. Closed-lo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Dynamic Systems, Measurement, and Control
سال: 2016
ISSN: 0022-0434,1528-9028