Close shock detection using time-frequency Prony modeling
In many cases, modeling a mechanical process may require a good understanding of signals issued from the system, as vibration accelerations. This is particularly the case when shocks are responsible of the vibrations. In the case of critical systems, each shock induces natural modes excitation with damped sines amplitudes. Identification of the shocks (occuring instants and induced vibrations) ...
متن کاملParametric Modeling of ICTAL Epilepsy EEG Signal Using Prony Method
Prony 's method is employed in spectral domain estimation to model epilepsy seizure from human 's Electroencephalograph (EEG).This method assumes that the original signal is a sum of damped complex exponential sinusoids. The method has the best frequency resolution compared to Auto Regression (AR) parametric methods. Modeling of the ictal EEG Epilepsy signal is based on the poles of the signal....
متن کاملOSAMA A. ELSAYED et al: MODELING OF EPILEPSY EEG SIGNAL USING PRONY METHOD
Prony 's method is employed in spectral domain estimation to model epilepsy seizure from human's electroencephalograph (EEG).This method assumes that the original signal is a sum of damped complex exponential sinusoids. The method has the best frequency resolution compared to Auto Regression (AR) parametric methods. Modeling of the EEG Epilepsy signal is based on the poles of the signal. Comput...
متن کاملViscoelastic Relaxation Modulus Characterization Using Prony Series
The mechanical behavior of viscoelastic materials is influenced, among other factors, by parameters like time and temperature. The present paper proposes a methodology for a thermorheologically and piezorheologically simple characterization of viscoelastic materials in the time domain based on experimental data using Prony Series and a mixed optimization technique based on Genetic Algorithms an...
متن کاملHarmonics detection using prony frequency analysis algorithm in transformer inrush current generation after fault clearance
The traditional infrastructure of power system industry is presently going through large amount of change that consensus over the improvement of power quality for fulfilling this requirement electronically automated devices having high sensitivity toward the disturbance in the power system signals are under the major consensus of research activities. The low power quality signal is responsible ...