Clinimetrics: Indirect calorimetry

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect calorimetry in critical care.

In critical care, particular attention is paid to disorders which lead to cerebral dysfunction. Hypoxia is the most common example and considerable effort is devoted to avoiding this problem. If the brain is deprived of fuel, as in hypoglycaemia, the outcome is similar yet far less attention is paid to maintaining an adequate and appropriate long-term fuel supply. Indirect calorimetry has been ...

متن کامل

What does indirect calorimetry really tell us?

Accurate and sensitive assessments of energy expenditure (EE) in mice changes in the balance of gut microbial species could differentially are essential given their importance to research on the molecular mechanisms of energy homeostasis [1]. EE phenotyping in mice is widely available using state-of-the-art equipment in many laboratories, including those in regional centers in the United States...

متن کامل

Challenges of indirect calorimetry in mice.

TO THE EDITOR: the recent paper by Longo et al. (5) provides an excellent description of the challenges of performing indirect calorimetry in mice. Mice that gain weight or are weight stable in their home cages often lose weight during the indirect calorimetry measurements, indicating that the procedure alters the usual behavior of the animals. To tackle this difficulty, the authors proposed a ...

متن کامل

Energy expenditure in critically ill patients estimated by population-based equations, indirect calorimetry and CO2-based indirect calorimetry

BACKGROUND Indirect calorimetry (IC) is the reference method for measurement of energy expenditure (EE) in mechanically ventilated critically ill patients. When IC is unavailable, EE can be calculated by predictive equations or by VCO2-based calorimetry. This study compares the bias, quality and accuracy of these methods. METHODS EE was determined by IC over a 30-min period in patients from a...

متن کامل

An Accurate Metabolic Simulator for Indirect Calorimetry System Validation

A metabolic simulator capable of simulation of respiratory oxygen consumption (VO2) and carbon dioxide production (VCO2) for validation of indirect calorimetry systems is described. The metabolic simulator adds/removes respiratory gases by way of mass flow controllers to/from a physiologically realistic lung simulator (Michigan Instruments Inc. Training/Test Lung). The metabolic simulator and M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physiotherapy

سال: 2019

ISSN: 1836-9553

DOI: 10.1016/j.jphys.2019.07.002