Clinical study with short implants – Relation among insertion torque, osseointegration and bone loss

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles.

This study aimed to evaluate biomechanical behaviour of inclined orthodontic mini-implants by analyzing its insertion torque (IT), axial pull-out strength (APS), and cortical bone thickness in contact with mini-implant (CBTC). A total of 102 mini-implants were inserted at 90 degree, 60 degree, and 45 degree to the surface of synthetic bone. Peak IT was measured, and the mini-implants were align...

متن کامل

Crestal Bone Loss Around Dental Implants; A Short Communication

Many studies described several parameters which are supposed to determine success or failure in longterm evaluations of dental implants. However, the relationship between crestal bone loss around implants and the location of implant-abutment connection in the bone still needs further investigations.The subgingival microgap between the implant and the abutment, which creates higher bone level re...

متن کامل

Growing Rats Are Resistant to Bone Loss Associated With Short-Term Hypercholesterolemia: A Preliminary Experimental Study

We aimed to evaluate the potential of growing rats as a model of osteoporosis induced by short term hypercholesterolemia. Twelve growing female Sprague-Dawley rats were randomly allocated into two groups. Control rats received standard diet while rats in group 2 were fed with diet contained 20% sunflower oil, 2% cholesterol and 0.5% cholic acid for 2 weeks and then a diet contained 10% sunflowe...

متن کامل

Effect of vertical placement angle on the insertion torque of mini-implants in human alveolar bone

Objective: The aim of the present ex-vivo study was to evaluate the effect of the vertical placement angle of mini-implants on primary stability by analyzing maximum insertion torque (MIT). Methods: Mini-implants were placed in 30 human cadavers, inserted at either a 90° or 60° angle to the buccal surface of the maxillary first molar. Out of 60 self-drilling mini-implants used, half were of ...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Oral Implants Research

سال: 2019

ISSN: 0905-7161,1600-0501

DOI: 10.1111/clr.412_13509