CLINICAL STUDIES ON THE VELOCITY OF BLOOD FLOW
نویسندگان
چکیده
منابع مشابه
the effects of changing roughness on the flow structure in the bends
flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...
A Numerical Analysis for the Effect of Slip Velocity and Stenosis Shape on Non-Newtonian Flow of Blood (TECHNICAL NOTE)
The aim of this paper is to study the effect of slip velocity and shape of stenosis on non-Newtonian flow of blood through a stenosed arterial segment. Blood is modeled as Bingham-Plastic fluid in a uniform circular tube with a radially non-symmetric stenosis. The problem is investigated by a joint effort of analytical and numerical techniques. The influence of stenosis shape parameter, slip ve...
متن کاملQuantitative blood flow velocity imaGinG
Laser speckle flowmetry suffers from a debated quantitative relationship with blood flow, velocity or tissue perfusion and a lack of calibration of the inverse relationship 1/τc = αV between decorrelation time (τc) and flow velocity (V). Using a modified microcirculation imager, we experimentally investigate on the influence of the optical properties of scatterers on α in vitro and in vivo. We ...
متن کاملQuantitative blood flow velocity imaGinG
Laser speckle flowmetry suffers from a debated quantitative relationship with blood flow, velocity or tissue perfusion and a lack of calibration of the inverse relationship 1/τc = αV between decorrelation time (τc) and flow velocity (V). Using a modified microcirculation imager, we experimentally investigate on the influence of the optical properties of scatterers on α in vitro and in vivo. We ...
متن کاملQuantitative blood flow velocity imaGinG
Laser speckle flowmetry suffers from a debated quantitative relationship with blood flow, velocity or tissue perfusion and a lack of calibration of the inverse relationship 1/τc = αV between decorrelation time (τc) and flow velocity (V). Using a modified microcirculation imager, we experimentally investigate on the influence of the optical properties of scatterers on α in vitro and in vivo. We ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Investigation
سال: 1928
ISSN: 0021-9738
DOI: 10.1172/jci100164