Clinical safety of magnetic resonanceimaging early after coronary artery stent placement

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical safety of magnetic resonance imaging early after coronary artery stent placement.

OBJECTIVES Our aim was to examine the rate of adverse cardiac events in patients undergoing magnetic resonance imaging (MRI) <8 weeks after coronary stent placement. BACKGROUND The risk of coronary stent thrombosis from dislodgement due to MRI early after stent placement is not well defined. Manufacturers recommend postponing MRI studies until eight weeks after coronary stent placement. MET...

متن کامل

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement.

BACKGROUND In-stent restenosis is notoriously difficult to treat by repeat catheter intervention because of its propensity for aggressive recurrent neointimal formation. This study sought to assess the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis. METHODS AND RESULTS The study was designed as a prospective multicenter registry. We included 16...

متن کامل

Magnetic resonance--guided coronary artery stent placement in a swine model.

BACKGROUND Magnetic resonance (MR)--guided coronary artery stent placement is a challenging vascular intervention because of the small size of the coronary arteries combined with incessant motion during the respiratory and cardiac cycles. These obstacles necessitate higher temporal and higher spatial resolution real-time MR imaging techniques when compared with interventional peripheral MR angi...

متن کامل

Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries.

BACKGROUND Although coronary stents have been proved effective in reducing clinical cardiac events for up to 3 to 5 years, longer term clinical and angiographic outcomes have not yet been fully clarified. METHODS AND RESULTS To evaluate longer term (7 to 11 years) outcome, clinical and angiographic follow-up information was analyzed in 405 patients with successful stenting in native coronary ...