Clinical Results of Cataract Surgery Using the ARTIS ® PL E Intraocular Lens

نویسندگان

چکیده

Purpose: To compare the clinical outcomes of cataract surgery using ARTIS ® PL E (Cristalens Industrie, Lannion, France) intraocular lens (IOL) and conventional Tecnis ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA) IOL.Methods: This retrospective study examined patients who underwent in-the-bag implantation either an (33 eyes, group A) or (45 B) IOL after phacoemulsification performed by a single surgeon. Best-corrected visual acuity (BCVA), spherical equivalent, higher-order aberrations (HOA) were measured 1 3 months surgery.Results: Preoperative BCVA did not differ significantly in groups A B. Postoperative at improved (<i>p</i> < 0.001) both compared to preoperative baseline BCVA. At postoperatively, total HOA, aberration, coma lower HOA 0.05) groups. However, there no significant differences trefoil values postoperatively The absolute refractive error was 0.27 ± 0.20 (group 0.28 B), within 0.50 diopters targeted goal diopter; accuracy predictability power calculation = 0.390, <i>p</i> 0.959). significantly; stability IOLs 0.482, 0.372).Conclusions: Conventional increased BCVA, while obtaining comparable results verified postoperative HOA.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broken intraocular lens during cataract surgery.

A case of planned routine extracapsular cataract extraction is described where surgery was complicated peroperatively by fracture of the posterior chamber lens implant. The technique of lens implantation is discussed.

متن کامل

Aspheric intraocular lens selection: the evolution of refractive cataract surgery.

In the current era of presbyopia-correcting intraocular lenses (IOLs), toric IOLs and aspheric IOL technology, the practice milieu is changing. Informed consent takes on newmeaning when the surgeon and the patient decide together which IOL technology represents the best fit for a particular life style and its visual demands. Customizing IOL choice is no longer optional; it is essential to the p...

متن کامل

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

Optical quality of toric intraocular lens implantation in cataract surgery.

AIM To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system. METHODS Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of AcrySof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes, T6 group 5 eyes. Main outcomes evaluated at 3mo of follow...

متن کامل

Clinical results using the Holladay 2 intraocular lens power formula.

PURPOSE To analyze the accuracy of the Holladay 2 formula, which has been proposed as an improvement over the original Holladay formula. METHODS This retrospective analysis comprised 317 eyes operated on by 1 surgeon using 1 technique and 1 intraocular lens style in a specialty practice. Because the Holladay 2 formula has yet to be published, its accuracy can only be analyzed using the commer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of The Korean Ophthalmological Society

سال: 2022

ISSN: ['0378-6471', '2092-9374']

DOI: https://doi.org/10.3341/jkos.2022.63.2.134