Clinical experience with an implanted closed-loop insulin delivery system.
AIM To report the first clinical experience with a prototype of implanted artificial beta-cell. METHODS The Long-Term Sensor System project assessed the feasibility of glucose control by the combined implantation of a pump for peritoneal insulin delivery and a central intravenous glucose sensor, connected physically by a subcutaneous lead and functionally by PID algorithms. It was performed i...
متن کاملClosed-loop insulin delivery for treatment of type 1 diabetes
Type 1 diabetes is one of the most common endocrine problems in childhood and adolescence, and remains a serious chronic disorder with increased morbidity and mortality, and reduced quality of life. Technological innovations positively affect the management of type 1 diabetes. Closed-loop insulin delivery (artificial pancreas) is a recent medical innovation, aiming to reduce the risk of hypogly...
متن کاملFeasibility of Outpatient 24-Hour Closed-Loop Insulin Delivery
Studies using outpatient closed-loop insulin delivery for type 1 diabetes have recently been published (1–5). We conducted a 5-day outpatient feasibility study comparing hybrid closed-loop (HCL) to sensor-augmented pump therapy with low-glucose suspend (SAPT1 LGS) in eight patients with type 1 diabetes using an open-label randomized crossover trial design (ACTRN12614001005640). We used theMedtr...
متن کاملClosed-Loop Insulin Delivery Using a Subcutaneous Glucose Sensor and Intraperitoneal Insulin Delivery
OBJECTIVE Attempts to build an artificial pancreas by using subcutaneous insulin delivery from a portable pump guided by an subcutaneous glucose sensor have encountered delays and variability of insulin absorption. We tested closed-loop intraperitoneal insulin infusion from an implanted pump driven by an subcutaneous glucose sensor via a proportional-integral-derivative (PID) algorithm. RESEA...
متن کاملEvaluation of an Ultrasonic Insulin Delivery System in Hyperglycemic Rabbits
Introduction: Sonophoresis has been assessed as a novel approach to create skin permeability and drug delivery using low frequencies of ultrasound waves in the range of 20 kHz to 3 MHz. In this study, a system including seven 40 kHz piezoelectric transducers and an insulin chamber designed by the Medical Physics Research Center has been evaluated on hyperglycemic rabbits. Materials and Methods:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Arquivos Brasileiros de Endocrinologia & Metabologia
سال: 2008
ISSN: 0004-2730
DOI: 10.1590/s0004-27302008000200023