Clinical evaluation of rebound tonometer
نویسندگان
چکیده
منابع مشابه
Evaluation of monkey intraocular pressure by rebound tonometer
PURPOSE To evaluate the usefulness of the TonoVet rebound tonometer in measuring intraocular pressure (IOP) of monkeys. METHODS The accuracy of the TonoVet rebound tonometer was determined in cannulated eyes of anesthetized rhesus monkeys where IOP was controlled by adjusting the height of a connected perfusate reservoir. To assess the applicability of the equipment through in vivo studies, t...
متن کاملGoldmann tonometer error correcting prism: clinical evaluation
PURPOSE Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. METHODS A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness,...
متن کاملNoninvasive measurement of rodent intraocular pressure with a rebound tonometer.
PURPOSE The present study evaluated the applicability of a rebound tonometer in measuring intraocular pressure (IOP) in rats and mice. METHODS The accuracy of the TonoLab rebound tonometer was determined in cannulated mouse and rat eyes. IOP was manipulated by changing reservoir height, and tonometer pressure readings were recorded by an independent observer. IOP values were recorded in consc...
متن کاملThe utility of rebound tonometer in late elderly subjects
BACKGROUND To compare intraocular pressure (IOP) readings using the Icare rebound tonometer (RBT) versus the Goldmann applanation tonometer (GAT) in late elderly (aged 75 years or older) subjects with or without glaucoma, and to evaluate the influence of central corneal thickness (CCT) on IOP readings. METHODS The IOP measurements were obtained using the RBT and GAT, and CCT was measured usin...
متن کاملComparison of IOPen rebound tonometer with Goldmann applanation tonometer at different IOP levels.
AIM To compare the accuracy of IOPen rebound tonometer with Goldmann applanation tonometer (GAT) in individuals with low, normal and high intraocular pressure (IOP) and to evaluate the effect of central corneal thickness (CCT) on IOP measurements. METHODS This cross-sectional study consisted of 159 participants. IOP of one eye of each subject was measured consecutively with IOPen and GAT. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Ophthalmologica Scandinavica
سال: 2006
ISSN: 1395-3907
DOI: 10.1111/j.1600-0420.2005.00610.x