Clinical Evaluation of Knee Arthroplasty using Whiteside Ortholoc II Prosthesis.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis

PURPOSE The purpose of the present study is to compare the prevalence of implant overhang between the Oxford and the Miller-Galante II (M-G II) unicompartmental knee arthroplasty (UKA) prostheses and determine whether overhang is associated with postoperative clinical results. MATERIALS AND METHODS We retrospectively reviewed one hundred and seven UKAs which consisted of 37 Oxford UKAs and 70...

متن کامل

3D CT Segmentation for Clinical Evaluation of Knee Prosthesis Operations

In surgical knee replacement, the damaged knee joint is replaced with artificial prostheses. An accurate clinical evaluation must be carried out before applying knee prostheses to ensure optimal outcome from surgical operations and to reduce the probability of having long-term problems. Useful information can be inferred from CT scans of the knee area, that can be used to estimate the stress th...

متن کامل

Revision Total Knee Arthroplasty Using the Modern Constrained Condylar Knee Prosthesis

OBJECTIVE To determine whether the second-generation constrained condylar prosthesis provided satisfactory results in revision total knee arthroplasty. METHODS A series of 41 cases of revision total knee arthroplasty using the second-generation constrained condylar knee prosthesis was reviewed. The series comprised 7 men and 34 women with a mean age of 73.2 years. The original diagnosis was p...

متن کامل

Arthroplasty of the knee by the Walldius prosthesis.

This paper presents a review of forty-five arthroplasties of the knee performed between 1961 and 1967, using the prosthesis designed in Sweden by Borge Walldius. The results presented are the combined experience of four surgeons : Mr F. C. Durbin, eleven knees; Mr R. Merryweather, thirteen knees; Mr R. S. Ling, four knees; and myself, seventeen knees. There were forty-five arthroplasties in for...

متن کامل

Evaluation of the Polycentric above Knee Prosthesis

The optimal design of human lower limb prostheses, in particular of knee devices, is fundamental in order to restore the lost functionality and aesthetic aspect of the amputee’s locomotion. Among all knee devices, the four-bar linkage is still the most widespread mechanism, since, despite its simplicity, it allows the prosthesis to be sufficiently stable and, at the same time, to replicate the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Orthopedics & Traumatology

سال: 1993

ISSN: 1349-4333,0037-1033

DOI: 10.5035/nishiseisai.42.970