منابع مشابه
Investigation of Circuit Breaker Dielectric Performance
The violent event of a short-circuit leads to short-term exposure of circuit breaker components to extremely high current, causing thermal degradation, vaporization and deformation of some components and the deposition of surface contaminants. After short-circuit, the leakage current carried by the breaker, when voltage is applied, increases dramatically but must remain below a certain threshol...
متن کاملAutomated Analysis of Circuit Breaker Operation
In this paper a new approach to the analysis of test results for circuit breakers is discussed. It is implemented through new software called Automated Circuit Breaker Monitoring system ACBM. The circuit breaker performance is evaluated based on the analysis of Digital Fault Recorder (DFR) recordings taken from circuit breaker control circuitry. This paper describes the testing procedure and us...
متن کاملAutomated Analysis of Circuit Breaker Operations
The automated circuit breaker diagnostic system described in this paper is an extension of the widely used portable circuit breaker testing device concept. These traditional testing devices can be connected to the circuit breaker’s control circuit to record analog and digital signals. The operator opens and closes the circuit breaker each time the test is performed and makes the recordings. The...
متن کاملAnalysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation
This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density a...
متن کاملAnalysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure
Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Innovative Science and Research Technology
سال: 2020
ISSN: 2456-2165
DOI: 10.38124/ijisrt20aug735