Chronic hemolysis following mitral valve replacement with St. Jude Medical prosthetic valve.
نویسندگان
چکیده
منابع مشابه
Chronic Hemolysis Following Mitral Valve Replacement
The incidence and severity of chronic intravascular hemolysis was evaluated in a total of 41 patients following mitral valve replacement. Valve replacement was with a gamma-radiated frame-mounted aortic homograft in 21 patients and with a composite seat Starr-Edwards prosthesis, model 6310 or 6320, in 20 patients. The parameters used to assess hemolysis were hemoglobin, hematocrit, reticulocyte...
متن کاملIsolated mitral and aortic valve replacement with the St. Jude Medical valve: a midterm follow-up.
BACKGROUND In our country, the biological valvular prostheses predominate, considering the difficulties related to anticoagulation, even in young patients, in spite of the need for repeated operations due to the degeneration of the bioprostheses. OBJECTIVES To report our consecutive series of recipients of isolated St Jude Medical mechanical valve prosthesis in the mitral (MVR) or aortic (AVR...
متن کاملCombined warfarin and antiplatelet therapy after St. Jude Medical valve replacement for mitral valve disease.
OBJECTIVES The clinical effect of combined warfarin and antiplatelet therapy on the incidence of stroke and postoperative complications after mitral (plus aortic) valve replacement was studied and compared with that observed with warfarin therapy alone. BACKGROUND It has been reported that combined warfarin and antiplatelet therapy may be effective but may be associated with an increased hemo...
متن کاملCardioversion following prosthetic mitral valve replacement.
SUMMARY Direct current conversion of atrial fibrillation has been attempted in 60 consecutive patients following prosthetic mitral valve replacement (Starr-Edwards prosthesis). Sinus rhythm was attained and persisted for at least 24 hours after the procedure in 68% (41 patients) and 40% of the entire group (24 patients) were still in normal sinus rhythm an average of 10 months later. Successful...
متن کاملThe St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
BACKGROUND From October 1977 to October 2002, 4,480 patients (age range, 17 to 94 years; average, 64 +/- 13 years) underwent single valve replacement with the St. Jude Medical heart valve. Of 2,982 aortic (AVR) and 1,498 mitral valve replacements (MVR), concomitant coronary artery bypass grafting was performed on 42% and 33%, respectively. METHODS Cardiac Surgical Associates has maintained an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Cardiovascular Surgery
سال: 1989
ISSN: 1883-4108,0285-1474
DOI: 10.4326/jjcvs.18.716