Chromatographic Separation of Puberty Accelerating Pheromone from Male Mouse Urine1
نویسندگان
چکیده
منابع مشابه
The Structure, Stability and Pheromone Binding of the Male Mouse Protein Sex Pheromone Darcin
Mouse urine contains highly polymorphic major urinary proteins that have multiple functions in scent communication through their abilities to bind, transport and release hydrophobic volatile pheromones. The mouse genome encodes for about 20 of these proteins and are classified, based on amino acid sequence similarity and tissue expression patterns, as either central or peripheral major urinary ...
متن کاملChromatographic separation of glycated nucleotides.
A high-performance liquid chromatographic method for the separation of nucleotide glycation reaction product(s) has been developed. The product(s) arising during in vitro glycation of a nucleotide (AMP, GMP or CMP) with a reducing sugar (ribose or glucose) were clearly resolved from the non-glycated constituents of the reaction mixture. The peak(s) of the glycated product(s) increased when an a...
متن کاملChromatographic Separation of the Diastereoisomers
Reduction of folic acid to the tetrahydro level introduces a second asymmetrical center into the molecule at carbon atom 6.1 The resulting tetrahydrofolate, and subsequent derivatives, prepared chemically consist of dl mixtures that are only 50% active in biological reactions. The need for fully reactive isomers of reduced folates led to the enzymatic synthesis of tetrahydrofolate from 7, %dihy...
متن کاملChromatographic Separation, and Characteristics of Nucleic Acids from HeLa Cells
The application of the phenol-duponol method to extraction of nucleic acids from HeLa cells is described. Chromatography of the phenol extract on an esterified bovine serum albumin column with a salt gradient of sodium chloride gives separation of soluble RNA, DNA, and two different high molecular RNA fractions. Ultracentrifugation of the DNA eluted from the column gives a sedimentation coeffic...
متن کاملCountercurrent chromatographic separation of catecholamine metabolites from urine.
A continuous-flow method is described for achieving high-resolution separations with liquid-liquid partition without the use of an inert support. The instrument consists of a 60-rn coil of Teflon tubing (0.85 mm i.d.) mounted planetarily on a centrifuge arm. The coil is filled with the stationary phase and the mobile phase is pumped through the column in a direction opposing the flow of the sta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biology of Reproduction
سال: 1976
ISSN: 0006-3363,1529-7268
DOI: 10.1095/biolreprod15.2.260