Chilled Water Storage Feasibility with District Cooling Chiller in Tropical Environment
نویسندگان
چکیده
منابع مشابه
Optimization of Water - Cooled Chiller – Cooling Tower Combinations
Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...
متن کاملqfd planning with cost consideration in fuzzy environment
در عصر حاضر که رقابت بین سازمان ها بسیار گسترش یافته است، مطالعه و طرحریزی سیستم های تولیدی و خدماتی به منظور بهینه سازی عملکرد آنها اجتناب ناپذیر می باشد. بخش عمده ای از رقابت پذیری سازمان ها نتیجه رضایتمندی مشتریان آنها است. میزان موفقیت سازمان های امروزی به تلاش آنها در جهت شناسایی خواسته ها و نیازهای مشتریان و ارضای این نیازها بستگی دارد. از طرفی کوتاه کردن زمان ارائه محصول/خدمات به مشتریان...
15 صفحه اولPerformance Evaluation of A Stratified Chilled- Water Thermal Storage System
In countries with hot climates, air-conditioning forms a large proportion of annual peak electrical demand, requiring expansion of power plants to meet the peak demand, which goes unused most of the time. Use of well-designed cool storage can offset the peak demand to a large extent. In this study, an air conditioning system with naturally stratified storage tank was designed, constructed and t...
متن کاملEnergy Management of a Chilled Water Plant Using Thermal Storage
This paper illustrates a project implemented in a major IBM plant in Canada using a TES system integrated with other technologies to optimize the chilled water production. The implementation of the Novanergy system (thermal storage with phase change material) has given important peak load reductions as well as significant reduction in the energy consumption and in the environmental impact of th...
متن کاملParametric studies on thermally strati®ed chilled water storage systems
An analysis of the strati®cation decay in thermally strati®ed vertical cylindrical cool storage systems is presented using a one dimensional conjugate heat conduction model. The degree of thermal strati®cation depends upon the length to diameter ratio, wall thickness to length ratio, the thermo-physical properties of the material of the storage tank, the type and thickness of the insulation and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Sustainable Development of Energy, Water and Environment Systems
سال: 2020
ISSN: 1848-9257
DOI: 10.13044/j.sdewes.d7.0259