منابع مشابه
Chemiluminescence technique for measuring reactive oxygen species.
Accurate assessment of reactive oxygen species (ROS) concentrations may help in the diagnosis of infertility. The chemiluminescence technique, which uses a luminometer to measure ROS, is a common method of assessment. A better understanding of the chemiluminescence technique will allow its proper application in reproductive medicine. A wide range of luminometers are available in the market, and...
متن کاملprediction of dissolved oxygen through mathematical modeling
water quality aspect with regard to dissolved oxygen was studied for a 24 kilometer stretch of malaprabha river in karnataka state, india. main objective of the research was to simulate the predicted dissolved oxygen depletion due to the waste load allocation in the river with the ambient observed values of dissolved oxygen, and to ascertain the application of mathematical modeling for predicti...
متن کاملcharacteristics and seasonal variations of dissolved oxygen
large amounts of degradable wastes including sewage water and agricultural waste or nutrients that stimulate growth of organic matter are discharged into the caspian sea. as a result, average dissolved oxygen concentration in deeper layers is decreasing. this paper presents distribution and seasonal variations of the concentration of dissolved oxygen over the southern shelf of the caspian sea a...
متن کاملA Dissolved Oxygen Measurement Based on Fiber Optical Oxygen Sensor
For the determination of dissolved oxygen, working principle of the fiber optic oxygen sensor is studied. The sensor system calibration method and temperature compensation measures and their maintenance methods are analyzed. The dissolved oxygen sensors current widely using oxygen electrode and optical fiber oxygen sensor are compared. Optical fiber probe sensor is used in the current system, t...
متن کاملTracer monitored titrations: measurement of dissolved oxygen.
The tracer monitored titration (TMT) technique is evaluated for measurement of dissolved oxygen. The TMT developed in this work uses a simple apparatus consisting of a low-precision pump for titrant delivery and an optical detector based on a white LED and two photodiodes with interference filters. It is shown that the classic Winkler method can be made free of routine volumetric and gravimetri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature
سال: 1964
ISSN: 0028-0836,1476-4687
DOI: 10.1038/201180b0