Chemiluminescence Determination of Local Anaesthetic Mepivacaine in Human Plasma and Pharmaceuticals
نویسندگان
چکیده
منابع مشابه
Mepivacaine local anaesthetic duration in equine palmar digital nerve blocks.
REASONS FOR PERFORMING STUDY Perineural analgesics are used for lameness diagnosis but the duration of effect, knowledge of which would provide valuable information when performing subsequent blocks, is unknown. OBJECTIVE To evaluate the duration of a palmar digital nerve block using force plate measurements. METHODS Ten horses diagnosed with unilateral navicular syndrome were trotted at ra...
متن کاملDevelopment and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma
Objective(s) Developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and Methods A shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, ...
متن کاملVoltammetric Determination of Labetalol in Pharmaceuticals and Spiked Human Urine
The electrochemical oxidation of labetalol was investigated by cyclic, linear sweep and differential pulse voltammetry at carbon paste electrode in Britton—Robinson buffers over the pH range 2.0—10.0. For analytical purposes, a well-defined adsorption-controlled anodic peak was obtained in Britton—Robinson buffer at pH 2.0. By anodic adsorptive linear sweep and differential pulse voltammetry, l...
متن کاملSpectrofluorimetric determination of tacrine in pharmaceuticals and spiked human serum.
A spectrofluorimetric method to determine tacrine is proposed and applied to the determination of tacrine in human serum and pharmaceuticals. The fluorimetric method allows the determination of 1-70 ng ml-1 of tacrine in aqueous solutions containing acetic acid-sodium acetate buffer (pH 5.6) with lambda exc = 242 nm and lambda em = 362 nm.
متن کاملDirect determination of plasma endothelin-I by chemiluminescence enzyme immunoassay.
A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fragment against the N-terminal core region of ET-1, is coupled with horseradish ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Chimica Slovenica
سال: 2016
ISSN: 1318-0207
DOI: 10.17344/acsi.2015.2161