Chemiluminescence assay of glucose oxidase using lucigenin-copper(II)ion and its application to enzyme immunoassay.
نویسندگان
چکیده
منابع مشابه
Lucigenin chemiluminescence assay for superoxide detection.
Superoxide Detection To the Editor: The recent review by Tarpey and Fridovich published in Circulation Research1 mostly contains interesting and sound material; however, I would like to comment on the section entitled, “Superoxide Detection, Chemiluminescence Reactions.” Basing mainly on their own data,2 authors maintain that lucigenin-amplified chemiluminescence (LucCL) overestimates the rate ...
متن کاملconstruction and validation of translation metacognitive strategy questionnaire and its application to translation quality
like any other learning activity, translation is a problem solving activity which involves executing parallel cognitive processes. the ability to think about these higher processes, plan, organize, monitor and evaluate the most influential executive cognitive processes is what flavell (1975) called “metacognition” which encompasses raising awareness of mental processes as well as using effectiv...
Chemiluminescence enzyme immunoassay for thyroxin with use of glucose oxidase and a bis(2,4,6-trichlorophenyl)oxalate-fluorescent dye system.
In this chemiluminescence enzyme immunoassay for thyroxin, glucose oxidase (EC 1.1.3.4) is the enzyme label and the bound and free fractions are separated by the double-antibody solid-phase technique. In the assay of enzyme activity, hydrogen peroxide generated from glucose substrate is measured by its chemiluminescence reaction with bis(2,4,6-trichlorophenyl)oxalate and 8-anilino-1-naphthalene...
متن کاملInvestigation of alveolar macrophage function using lucigenin-dependent chemiluminescence.
The method using lucigenin-dependent phagocytic chemiluminescence is described for the assessment of alveolar macrophage metabolic activity in response to stimulation by opsonised particles or soluble agents. The requirement for superoxide anion (O2-) in the production of chemiluminescence is suggested by inhibition (95%) using superoxide dismutase. The results obtained are correlated with thos...
متن کاملEnzyme immunoassay of urinary mevalonic acid and its clinical application.
We have developed an enzyme immunoassay for mevalonic acid (MVA), using a specific monoclonal antibody. The intra- and interassay coefficients of variation calculated on two urine samples were 3.3% and 3.4%, respectively, in the intraassay precision test and 3.5% and 6.9% in the interassay evaluation. Pravastatin, a 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) reductase inhibitor, was admini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1992
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.41.10_473