Chemically Modified Carbon Paste Electrode for Determination of Cesium Ion by Potentiometric Method

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemically Modified Carbon Paste Electrode for Determination of Cesium Ion by Potentiometric Method

A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyanoferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10 to 1 × 10 mol·L with a slope of 58 ± 0.5 mV·decade. It has a response time of about 35 s and can be used for a period of 3 months with...

متن کامل

A Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion

Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...

متن کامل

Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods

A chemically modified carbon paste electrode with multiwall carbon nanotube (MWCNT) was prepared and used as a sensor for Cu2+  ion. The unique chemical and physical properties of CNT have paved the way  to  new  and  improved  sensing  devices.  A  central  composite chemometrics  design  was  applied  for  multivariate  optimization  of the  effects  of  three  significant  parameters  (...

متن کامل

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

متن کامل

Chemically modified carbon paste electrode for iodide determination on the basis of cetyltrimethylammonium iodide ion-pair.

A new carbon paste electrode (CPE) for the determination of iodide ion based on a cetyltrimethylammonium iodide (CTMAI) ion pair as an electroactive material is described. The electrode shows a linear response for iodide ion over the concentration range of 4 x 10(-5) M to 1 x 10(-1) M with a lower detection limit of 4 x 10(-5) M at 25 degrees C. The electrode has a Nemstian slope of -55.0 +/- 0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: American Journal of Analytical Chemistry

سال: 2012

ISSN: 2156-8251,2156-8278

DOI: 10.4236/ajac.2012.38076