Chemical shift separation with controlled aliasing for hyperpolarized13C metabolic imaging

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled Aliasing In Parallel Imaging

Recently a new parallel imaging strategy, Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA), was introduced, which modifies the appearance of the aliasing artifacts during the acquisition in order to improve the following parallel imaging reconstruction procedure. This concept was successfully applied to simultaneous multi-slice imaging (MS-CAIPIRINHA) [1] and ...

متن کامل

Echoplanar chemical shift imaging.

A novel method of chemical shift imaging utilizing echoplanar imaging (EPI) has been developed for the purpose of improving the spatial resolution of metabolite images for the specific goal of high spatial resolution mapping of neuronal content. An EPI sequence was modified to allow temporal offsets of the 180 degree refocusing pulse that encode the chemical shift information into the phase of ...

متن کامل

Double Spin-Echo Spiral Chemical Shift Imaging for Rapid Metabolic Imaging of Hyperpolarized [1-C]-Pyruvate

Introduction Rapid chemical shift imaging (CSI) techniques are of considerable interest for hyperpolarized C metabolic imaging [1,2]. Undersampled spiral CSI (spCSI) using a free induction decay (FID) acquisition mode has been applied to real-time metabolic imaging with acquisition times of less than 1 s per slice [3]. The FID acquisition necessitates phase correction during reconstruction for ...

متن کامل

Cardiac Imaging with Chemical Shift Based Water-Fat Separation at 3T

Introduction Chemical shift based water-fat separation techniques have been demonstrated for 1.5T cardiac imaging of several pathologies, including fatty infiltration of chronic infarction; arrhythmogenic right ventricular cardiomyopathy (ARVC); fatty tumors; and conditions such as myocarditis and pericarditis [1-4]. Higher field strengths (3T) are now often used in cardiac MRI due to improved ...

متن کامل

Compressed sensing for chemical shift-based water-fat separation.

Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2014

ISSN: 0740-3194

DOI: 10.1002/mrm.25473