Characterization of the scintillation anisotropy in crystalline stilbene scintillator detectors
نویسندگان
چکیده
منابع مشابه
Scintillation detectors for x-rays
Recent research in the field of phosphor and scintillator materials and related detectors is reviewed. After a historical introduction the fundamental issues are explained regarding the interaction of x-ray radiation with a solid state. Crucial parameters and characteristics important for the performance of these materials in applications, including the employed measurement methods, are describ...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملAntineutrino geophysics with liquid scintillator detectors
Detecting the antineutrinos emitted by the decay of radioactive elements in the mantle and crust could provide a direct measurement of the total abundance of uranium and thorium in the Earth. In calculating the antineutrino flux at specific sites, the local geology of the crust and the background from the world’s nuclear power reactors are important considerations. Employing a global crustal ma...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملFast digitizing techniques applied to scintillation detectors
A 200 MHz 12-bit fast transient recorder card has been used for the digitization of pulses from photomultipliers coupled to organic scintillation detectors. Two modes of operation have been developed at ENEA-Frascati: a) continuous acquisition up to a maximum duration of ∼ 1.3 s corresponding to the full on-board memory (256 MSamples) of the card: in this mode, all scintillation events are reco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2017
ISSN: 0168-9002
DOI: 10.1016/j.nima.2016.11.016