Characterization of radio frequency plasma using Langmuir probe and optical emission spectroscopy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical emission spectroscopy and Langmuir probe diagnostics of CH3F/O2 inductively coupled plasmas

A CH3F:O2 (50%:50%) inductively coupled discharge, sustained in a compact plasma reactor, was investigated as a function of power (20–400 W) and pressure (9–30 mTorr), using optical emission spectroscopy and Langmuir probe measurements. The electron density increased linearly with power but only weakly with pressure. The effective electron temperature was nearly independent of power and pressur...

متن کامل

Characterization of transformer coupled oxygen plasmas by trace rare gases–optical emission spectroscopy and Langmuir probe analysis

Trace rare gases–optical emission spectroscopy (TRG–OES) and Langmuir probe analysis have been used to measure the electron temperature, Te, in a high-density inductively (transformer) coupled (TCP) 10 mTorr oxygen plasma as a function of the 13.56 MHz radio frequency (rf) power. The oxygen atomic densities were estimated by O-atom optical emission (8446 Å), and rare gas actinometry (Ar, 7504 Å...

متن کامل

Measurement of electron temperatures of Argon Plasmas in a High-Density Inductively-Coupled Remote Plasma System by Langmuir Probe and Optical-Emission Spectroscopy

We measured electron density and electron energy distribution function (EEDF) in our reactor by a Langmuir probe. The EEDF of Ar plasma in the reactor could largely be described by the Maxwell-Boltzmann distribution function, but it also contained a fraction (~10) of electrons which were much faster (20-40 eV). The peak of the fast-electron tail shifted from E ~ 35 eV at 11 μbar to E ~ 25 eV wh...

متن کامل

study and characterization of fiber optical gyroscope مطالعه و مشخصه یابی ژیروسکوپ فیبر نوری(تار نوری)

ژیروسکوپ فیبر نوری fog بر اساس پدیده تداخل ساگنام دو پرتو لیزری از یک فیبر نوری بسیار طولانی داده های لازم را فراهم می آورد

15 صفحه اول

Influence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe

Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Physics

سال: 2006

ISSN: 0021-8979,1089-7550

DOI: 10.1063/1.2171777