Characterization of Polycapillary X-Ray Semilenses with SEM/EDX
نویسندگان
چکیده
منابع مشابه
Polycapillary X-ray optics for microdiffraction
Polycapillary optics, i.e. shaped arrays consisting of hundreds of thousands of hollow glass capillary tubes, can be used to redirect, collimate or focus X-ray beams. X-rays emitted over a large angular range from conventional laboratory-based sources can be transformed into a beam with a small angular divergence or focused onto a small sample or sample area. Convergent beams of X-rays, with co...
متن کاملFull-field transmission x-ray imaging with confocal polycapillary x-ray optics.
A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for his...
متن کاملGrid-enhanced X-ray coded aperture microscopy with polycapillary optics
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imagin...
متن کاملBeam collimation with polycapillary x-ray optics for high contrast high resolution monochromatic imaging.
Monochromatic imaging can provide better contrast and resolution than conventional broadband radiography. In broadband systems, low energy photons do not contribute to the image, but are merely absorbed, while high energy photons produce scattering that degrades the image. By tuning to the optimal energy, one can eliminate undesirable lower and higher energies. Monochromatization is achieved by...
متن کاملPolycapillary lenses for soft x-ray transmission in ITER: Model, comparison with experiments, and potential application.
Measuring Soft X-Ray (SXR) radiation [0.1 keV; 15 keV] in tokamaks is a standard way of extracting valuable information on the particle transport and magnetohydrodynamic activity. Generally, the analysis is performed with detectors positioned close to the plasma for a direct line of sight. A burning plasma, like the ITER deuterium-tritium phase, is too harsh an environment to permit the use of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2010
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927610054280