Characterization of linear accelerator X-ray source size using a laminated beam-spot camera
نویسندگان
چکیده
منابع مشابه
Characterization of linear accelerator X‐ray source size using a laminated beam‐spot camera
A laminated beam-spot camera of length 20 cm and effective cross-sectional area 2.5 cm × 3 cm was designed and constructed for the measurement of X-ray beam-spot sizes on different models of Siemens accelerators. With the accelerator gantry at 180° and camera positioned on an accessory tray holder, an XV film placed in contact with the camera at the distal end of it detected those X-rays that w...
متن کاملX-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator.
PURPOSE The feasibility of medical imaging using a medical linear accelerator to generate acoustic waves is investigated. This modality, x-ray acoustic computed tomography (XACT), has the potential to enable deeper tissue penetration in tissue than photoacoustic tomography via laser excitation. METHODS Short pulsed (μs-range) 10 MV x-ray beams with dose-rate of approximately 30 Gy∕min were ge...
متن کاملPhotoneutron intensity variation with field size around radiotherapy linear accelerator 18-MeV X-ray beam
In X-ray radiotherapy accelerators, neutrons are produced mainly by ( , n) reaction when high energy X-rays interact with high Z materials of the linear accelerator head. These materials include the lead (Pb) used as shielding in the collimator, tungsten (W) target used for the production of X-rays and iron (Fe) in the accelerator head. These unwanted neutrons contaminate the therapeutic beam a...
متن کاملParallel Beam Powder Diffractometry Using a Laboratory X-Ray Source
We report on the application of a new, non-dispersive double multilayer optical arrangement to prepare a parallel beam from a laboratory x-ray source for standardization of powder diffraction reference materials and the associated high accuracy diffractometer. The beam preparation optic uses a graded-spacing parabolic multilayer to gather radiation from a small focus x-ray source and a subseque...
متن کاملDose Rate Influence on Deep Dose Deposition Using a 6 MV X-Ray Beam From a Linear Accelerator
Linear accelerators used in radiation therapy treatments usually provide the capability of irradiating with different dose rates. The medical physicist may choose arbitrary the dose rate to use, although the relative biological effectiveness (RBE) varies with this physical parameter. In this work the measurements of absorbed dose of the x-ray beams from a Varian 6 MV linear accelerator CLINAC 6...