Characterization of Cured Furan Resin Prepared by High Power Ultrasonic Irradiation
نویسندگان
چکیده
منابع مشابه
Preparation and Characterization of ZrO2/TiO2 Nanocomposite under Ultrasonic Irradiation by Sol-gel Route
TiO2/ZrO2 nanocomposite was obtained by the sonochemical technique. In this method, two separate gels containing zirconium and titanium were prepared and mixed together. The precursor sol of zirconium was prepared from an aqueous solution of ZrCl4. The precursor titanium tetra isopropoxide (TTIP) dissolved in isopropanol. Mixing of Titanium and Zirconium gels was resulted in a yellow TiO2/ZrO2 ...
متن کاملPreparation and Characterization of ZrO2/TiO2 Nanocomposite under Ultrasonic Irradiation by Sol-gel Route
TiO2/ZrO2 nanocomposite was obtained by the sonochemical technique. In this method, two separate gels containing zirconium and titanium were prepared and mixed together. The precursor sol of zirconium was prepared from an aqueous solution of ZrCl4. The precursor titanium tetra isopropoxide (TTIP) dissolved in isopropanol. Mixing of Titanium and Zirconium gels was resulted in a yellow TiO2/ZrO2 ...
متن کاملEffect of reduced exposure times on the cytotoxicity of resin luting cements cured by high-power led
OBJECTIVE Applications of resin luting agents and high-power light-emitting diodes (LED) light-curing units (LCUs) have increased considerably over the last few years. However, it is not clear whether the effect of reduced exposure time on cytotoxicity of such products have adequate biocompatibility to meet clinical success. This study aimed at assessing the effect of reduced curing time of fiv...
متن کاملMicroleakage of composite resin restoration in cavities prepared by Er:YAG laser irradiation in primary teeth.
AIM: The purposes of this study were to investigate the surface morphology of cavities prepared by Er:YAG laser irradiation and to compare the microleakage degree after composite resin restoration with etched bur cavities in primary teeth, in vitro. MATERIALS AND METHODS: On the buccal (facial) and lingual (palatal) surfaces of 25 primary teeth, a round cavity was prepared with the Er:YAG laser...
متن کاملcharacterization of a new prepared li2b4o7: mn dosimeter for γ- irradiation high-dose dosimetry
a lithium borate thermoluminescence dosimeter with 0.3 wt% of manganese impurityconcentration was prepared for high dose levels in the range of 1-30 kgy for gamma irradiation applications.the tld reader was used for read out purposes from ambient temperature to about 400°c with a heating rate of 6°c/sec. the pre- and post- irradiation anneal temperature was 300°c for 1.5 and 1 hours respectivel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TANSO
سال: 1999
ISSN: 1884-5495,0371-5345
DOI: 10.7209/tanso.1999.289