Characterization of a radiochromic silicone dosimeter
A radiochromic silicone based dosimeter has been fabricated that allows for threedimensional (3D) dose verification. This paper characterizes the silicone dosimeter and verifies previous results found by other research groups. Using a recipe found to be dose rate independent, we identify the spectra of the dosimeter irradiated to different doses and verify that the response from different dose ...
متن کاملCharacterization of a reusable PRESAGE® 3D dosimeter
This study investigates a reusable PRESAGE® 3D dosimeter (Presage-RU), which would improve cost-effectiveness and facilitate wider implementation of comprehensive, high resolution 3D dosimetry. Small (1x1x4.5 cm) and large (8 cm diameter, 4.5 cm length) sample dosimeters were irradiated multiple times to characterize dose response (i.e. radiation-induced change in optical density (∆OD)), optica...
متن کاملComputed Tomography Dosimeter Utilizing a Radiochromic Film and an Optical Common-mode Rejection Characterization and calibration of the GafChromic XRCT film
Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes color upon irradiation changing from amber to dark greenish-black depending on the level of exposure. The absorption spectra of Gaf...
متن کاملEnergy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter.
The response of radiochromic film, GafChromic EBT, was investigated for dependence on x-ray beam energy using a previously reported real-time optical readout approach. X-ray beams of energy from 75 kVp to 18 MV were employed. The dose-induced change in optical density for the EBT film was compared to values obtained for GafChromic HS and MD-55 films, exposed under the same conditions. All respo...
متن کاملA Novel Neutron Dosimeter
Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...