Characteristics of A‐150 plastic‐equivalent gas in A‐150 plastic ionization chambers for p (66)Be(49) neutrons
نویسندگان
چکیده
منابع مشابه
Microsoft Word - a150
Ablation of sources identified by dominant frequency (DF) or phase analyses in patients with atrial fibrillation (AF) is proposed as a therapy to terminate the arrhythmia. The aim of this study was to evaluate noninvasive identification of AF sources by solving the inverse problem. Realistic mathematical models of atria and torso anatomy with different DF patterns of AF were used. For these mod...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملContamination of ionization chambers by talcum powder.
This is a word of caution to anyone using ionization chambers protected by thin rubber sheaths in water. Four Farmer-type ionization chambers contaminated with talcum powder were received for calibration by the Accredited Dosimetry Calibration Laboratory at the University of Texas M. D. Anderson Cancer Center. The chambers show a marked energy dependence (5% to 20%) to soft orthovoltage x rays....
متن کاملMeasurements of output factors using different ionization chambers and build up caps
Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...
متن کاملIonization Chambers for Monitoring in High-IntensityCharged Particle Beams
Radiation-hard ionization chambers were tested using an intense electron beam from the accelerator test facility (ATF) at the Brookhaven National Laboratory (BNL). The detectors were designed to be used as the basic element for monitoring muons in the Main Injector Neutrino beamline (NuMI) at the Fermi National Accelerator Laboratory (FNAL). Measurements of linearity of response, voltage depend...