CHARACTERISTICS OF A TWO-PHASE SRM WITH DIFFERENT ROTOR DESIGNS BASED ON FINITE ELEMENT ANALYSIS
نویسندگان
چکیده
منابع مشابه
Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملTensile behavior simulation of woven fabric with different weave pattern based on finite element method
متن کامل
Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis
PURPOSE Clinical success of implant prosthodontics is dependent in part upon the type of implant thread design. The selection of implant thread design plays an important role in the outcome of the treatment. This study was undertaken to evaluate the pattern of stress distribution using a finite element analysis; hence, the area which would be bearing maximum load for a given design would be arr...
متن کاملA New Stress Based Approach for Nonlinear Finite Element Analysis
This article demonstrates a new approach for nonlinear finite element analysis. The methodology is very suitable and gives very accurate results in linear as well as in nonlinear range of the material behavior. Proposed methodology can be regarded as stress based finite element analysis as it is required to define the stress distribution within the structural body with structural idealization a...
متن کاملthree dimensional finite element analysis of distal abutment stresses of removable partial dentures with different retainer designs
objectives : this finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (rpds) and the same rpd abutment tooth (not isolated). materials and methods: a kennedy class 1, modification 1 rpd framework was simulated on a 3d model of mandible with three differ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ERJ. Engineering Research Journal
سال: 2008
ISSN: 1110-1180
DOI: 10.21608/erjm.2008.69506