Characteristics of a Force-balance Nozzle-flapper Type Pneumatic Pressure Control Proportional Valve. Part 2. Output Pressure versus the Output Flow-rate Characteristics.
نویسندگان
چکیده
منابع مشابه
Performance study of a diaphragm type crankcase pressure control valve
Pressure control valve (PCV) is implemented in internal combustion engine to regulate crankcase pressure. In this study, the performance of a diaphragm PCV valve is investigated numerically and experimentally. Firstly, numerical simulation is carried out using commercial code to predict the flow and pressure distribution inside the valve. Furthermore, downstream and upstream pressure of the val...
متن کاملPneumatic single flapper nozzle valve driven by piezoelectric tube
The article presents a construction, static testing and modelling of a single flapper nozzle pneumatic valve. Authors show testing of piezo tube PT230 which distinguishing feature is deflection in two directions. This testing is preliminary work in design of a novel electropneumatic valve. Studies have been performed on a special designed bench which consists of a pneumatic valve, which used pi...
متن کاملPressure flow characteristics of the valve in spacer devices.
The valve system in the mouth piece of two spacer devices was analysed. Pressures required to open and close the non-rebreathing valve were very low (less than 0.1 kPa). Inspiratory flow requirements were within physiological limits for infants' normal tidal breathing. Expiratory flow requirements varied significantly, and the flow required to prevent rebreathing from the chamber may exceed the...
متن کاملInput / Output Characteristics of ScalableParallel
Rapid increases in computing and communication performance are exacerbating the long-standing problem of performance-limited input/output. Indeed, for many otherwise scalable parallel applications , input/output is emerging as a major performance bottleneck. The design of scalable input/output systems depends critically on the input/output requirements and access patterns for this emerging clas...
متن کاملThe relationship of cardiac output and arterial pressure control.
Many basic concepts of cardiac output and arterial pressure control have changed considerably in the past few years. In general, each tissue controls its own local resistance and blood flow regardless of the level of arterial pressure; the sum of the local flows then determines the venous return and cardiac output. However, the arterial pressure is normally controlled by separate mechanisms tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Hydraulics & Pneumatics
سال: 1995
ISSN: 0286-6900,2185-5285
DOI: 10.5739/jfps1970.26.343