Chaos Control of Doubly-Fed Induction Generator via Delayed Feedback Control

نویسندگان

چکیده

With the increasing wind power penetration, farms are directly influencing systems, so need to improve quality of system is an open research topic. A Doubly-Fed Induction Generator (DFIG) often used in systems. However, DFIG has a complex structure and works harsh environments, potential faults may occur. Faults can cause fall into chaotic working state, which harmful phenomenon for DFIG, since it makes operating worse, even leading destruction if not fixed on time. This study presents simulations that occurs under specific conditions based Lyapunov’s exponents. The delay feedback controller designed, along with selection appropriate parameters, quickly eliminated, bringing back stable operation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid Fuzzy Reference Signal Tracking Control of a Doubly Fed Induction Generator

This paper presents a hybrid scheme for the control of active and reactive powers using the direct vector control with stator flux orientation (SFO) of the DFIG. The hybrid scheme consists of Fuzzy logic, Reference Signal Tracking (F-RST) controllers. The proposed (F-RST) controller is compared with the classical Proportional-Integral (PI) and the Polynomial (RST) based on the pole placement th...

متن کامل

Fuzzy Logic Control of Doubly Fed Induction Generator Wind Turbine

This paper presents fuzzy logic control of Doubly Fed Induction Generator (DFIG) wind turbine in a sample power system. DFIG consists of a common induction generator with slip ring and a partial scale power electronic converter. Fuzzy logic controller is applied to rotor side converter for active power control and voltage regulation of wind turbine. Wind turbine and its control unit are describ...

متن کامل

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

متن کامل

Delayed feedback control of chaos.

Time-delayed feedback control is well known as a practical method for stabilizing unstable periodic orbits embedded in chaotic attractors. The method is based on applying feedback perturbation proportional to the deviation of the current state of the system from its state one period in the past, so that the control signal vanishes when the stabilization of the target orbit is attained. A brief ...

متن کامل

Performance Evaluation of Doubly-Fed Induction Generator Using Combined Vector Control and Direct Power Control Method

Abstract This paper presents the performance evaluation of Doubly-Fed Induction Generator Using Combined Vector Control and Direct Power Control Method. Combined vector and direct power control (CVDPC) is used for the rotor side converter (RSC) of double-fed induction generators (DFIGs). The control system is according a direct current control by selecting suitable voltage vectors from a switch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Engineering, Technology & Applied Science Research

سال: 2023

ISSN: ['1792-8036', '2241-4487']

DOI: https://doi.org/10.48084/etasr.5812