Change in intraocular pressure during scleral depression.
PURPOSE Manometric studies have found that intraocular pressure (IOP) rises 116-350 mmHg during scleral depression in surgical settings. No information is available regarding the effect of scleral depression on IOP in routine clinical settings. The aim of this study is to quantify the change in IOP that occurs when scleral depression is performed on normal eyes in a routine clinical setting. ...
متن کاملEffect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression
The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated. Two IOLs of 6 mm and 7 mm optic diameter were implanted. The intraocular pressure (IOP) was monitored during scleral depression by a transducer placed in the midvitreous through a sclerotomy at 6 o'clock. The area under the curv...
متن کاملChange in Intraocular Pressure During Point-of-Care Ultrasound
INTRODUCTION Point-of-care ocular ultrasound (US) is a valuable tool for the evaluation of traumatic ocular injuries. Conventionally, any maneuver that may increase intraocular pressure (IOP) is relatively contraindicated in the setting of globe rupture. Some authors have cautioned against the use of US in these scenarios because of a theoretical concern that an US examination may cause or exac...
متن کاملScleral Fixation Intraocular lenses
Background: The 1ry indication for scleral fixation of intraocular lenses (IOL) is dislocation as a principal complication of cataract surgery. Inadequate capsular support is the most common cause of IOL dislocation. Other indications include traumatic phakic lens dislocation (cataractous or clear), surgically aphakic eyes or anterior chamber IOL with complications (persistent hyphema, uveitis)...
متن کاملIntraocular pressure during phacoemulsification.
PURPOSE To assess changes in intraocular pressure (IOP) during standard coaxial or bimanual microincision phacoemulsification. SETTING Oregon Eye Center, Eugene, Oregon, USA. METHODS Bimanual microincision phacoemulsification (microphaco) was performed in 3 cadaver eyes, and standard coaxial phacoemulsification was performed in 1 cadaver eye. A pressure transducer placed in the vitreous cav...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Optometry
سال: 2015
ISSN: 1888-4296
DOI: 10.1016/j.optom.2014.09.002