Cesiated surface H− ion source: optimization studies
نویسندگان
چکیده
منابع مشابه
An ion source for molecular effusion studies
An ion source which utilizes a beam of monoenergetic electrons as the ionizing agent was designed and built for use in a 60° sector general utility mass spectrometer. The source was made to be used without a magnetic field to collimate the electron beam. The source is interchangeable with a surface ionization source that was already utilized in the mass spectrometer. Various operating character...
متن کاملLifetime Study of Tungsten Filaments in an H Surface Converter Ion Source*
The tungsten filaments are critical components that limit the lifetime of the H surface converter ion source. Their finite lifetime has a huge impact on the maintenance schedules and overall availability of an accelerator facility. We present in this work a simple analytical filament lifetime model and 3D thermal simulation explaining basic phenomena of filament erosion and electrical resistanc...
متن کاملSimulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator.
A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyväskylä, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H(-) ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental da...
متن کاملPlasma meniscus and extraction electrode studies of the ISIS H- ion source.
In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H(-) ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the...
متن کاملRutgers 12-Inch Cyclotron Ion Source Studies: Part II (Ion Source Simulations and Measurements)
Since the publication of the first Ion Source Studies document there have been improvements in both the understanding and implementation of the ion source system.[1] The understanding has been greatly assisted by the 3-dimensional E&M particle tracking code SIMION. Several experiments in the adjustment of the ions’ initial condition have benchmarked our 3D model as well as identified the source...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: New Journal of Physics
سال: 2017
ISSN: 1367-2630
DOI: 10.1088/1367-2630/aa52e3