Cerebral Flow Pattern Monitoring by Transcranial Doppler during Cardiopulmonary Resuscitation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral monitoring during carotid endarterectomy by transcranial Doppler ultrasonography

PURPOSE To evaluate the efficacy and safety of cerebral monitoring by transcranial Doppler ultrasonography (TCD) for the detection of cerebral ischemia during carotid endarterectomy (CEA). METHODS From August 2004 to December 2013, 159 CEAs were performed in a tertiary hospital. All procedures were performed under general anesthesia. Intraoperative TCD was routinely used to detect cerebral is...

متن کامل

Transcranial Doppler assessment of cerebral flow velocity during cognitive tasks.

BACKGROUND AND PURPOSE The purpose of this study was to assess the ability of transcranial Doppler ultrasonography to detect selective circulatory changes during cognitive activity. METHODS We measured cerebral artery flow velocity in 21 normal volunteers by transcranial Doppler ultrasonography during rest followed by cerebral activation. Mean and peak systolic flow velocities of the anterior...

متن کامل

Cerebral emboli detected by transcranial Doppler during cardiopulmonary bypass are not correlated with postoperative cognitive deficits.

BACKGROUND AND PURPOSE High-intensity transient signals (HITS) are the transcranial Doppler representation of both air and solid cerebral emboli. We studied the frequency of HITS associated with different surgical maneuvers during cardiopulmonary bypass for coronary artery bypass graft surgery and their association with postoperative cognitive dysfunction (POCD). METHODS We combined 356 patie...

متن کامل

Cerebral oximetry during extracorporeal cardiopulmonary resuscitation

optimize brain perfusion in a patient receiving extracorporeal cardiopulmonary resuscitation (eCPR) after out-of-hospital cardiac arrest (OHCA). A 52-year-old woman (height of 165 cm and weight of 67 kg) had an OHCA secondary to acute myocardial infarction. Th e ambulance arrived on the scene 10 minutes after the call, and mechanical CPR (Lucas; Physio Control Inc., Brussels, Belgium) was initi...

متن کامل

Conjunctival oxygen monitoring during cardiopulmonary resuscitation.

The conjunctival oxygen tension (CjO2) sensor is a non-invasive, continuous index of oxygen delivery in the haemodynamically unstable patient. Human and animal studies have indicated that CjO2 reflects cerebral blood flow and oxygenation. Simple insertion, rapid stabilization and reaction time less than 60 s allow use in the initial stages of cardiopulmonary resuscitation (CPR) where invasive m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia and Intensive Care

سال: 2010

ISSN: 0310-057X,1448-0271

DOI: 10.1177/0310057x1003800223