Central Venous Catheter–AssociatedNocardiaBacteremia
نویسندگان
چکیده
منابع مشابه
Determination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملThe successful withdrawal of a migrated central venous catheter
Background: Central venous catheters (CVCs) have been used widely in clinics. These catheters are also recommended for children and infants receiving chemotherapy and total parenteral nutrition (TPN) and etc. In this paper, we present migrated fractured control line of the heart of a girl. Case Presentation: A 2.5 year old girl with migrated of the fractured central line into the heart. In the ...
متن کاملCentral venous obstruction management.
A major challenge in the management of hemodialysis patients is central venous stenosis and obstruction. Placement of central venous catheters has been shown to result in a high incidence of central venous stenosis or obstruction. There has been extensive literature on the treatment of this important and prevalent problem. Treatment options include percutaneous balloon angioplasty and bare meta...
متن کاملCentral venous catheters.
Central venous catheterisation was first performed in 1929when Werner Frossman, a German doctor, inserted a ureteric catheter into his antecubital vein. He then walked to the radiography department so that the catheter could be guided into his right ventricle using fluoroscopy. Since then, central venous access has become amainstay of modern clinical practice. An estimated 200 000 central venou...
متن کاملCentral venous catheter fracture.
665 The Journal of the American Osteopathic Association August 2014 | Vol 114 | No. 8 An 18-year-old woman presented with a 1-day history of edema and erythema associated with a port central venous access device of the anterior left chest wall. The patient reported difficulty with catheter flushing for 2 days. Medical history included severe gastroparesis requiring placement of the catheter 2 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Infectious Diseases
سال: 2001
ISSN: 1058-4838,1537-6591
DOI: 10.1086/323557