Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.

BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...

متن کامل

Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma.

OBJECTIVES To determine the effect of central corneal thickness (CCT) on the measurement of intraocular pressure (IOP) and on the resultant reclassification of patients as having primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), or ocular hypertension (OHT). METHODS Intraocular pressure (Goldmann applanation tonomety) and CCT (ultrasound pachymetry) were measured in 22 patien...

متن کامل

Central corneal thickness in primary open angle glaucoma, pseudoexfoliative glaucoma, ocular hypertension, and normal population.

PURPOSE This study was designed to determine the relationship between central corneal thickness (CCT) and intraocular pressure (IOP) measured by applanation tonometer in glaucomatous, ocular hypertensive, and normal eyes. METHODS A total of 125 subjects were included in the study. Twenty-six had primary open angle glaucoma (POAG), 25 had pseudoexfoliative glaucoma (PXG), 24 had ocular hyperte...

متن کامل

Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension

Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open a...

متن کامل

Evaluation of central corneal thickness in patients with ocular hypertension and primary open-angle glaucoma.

AIM To determine correlation between central corneal thickness (CCT) and applanation intraocular pressure (IOP) in normal patients with primary open angle glaucoma and patients with ocular hypertension. METHODS Two-year retrospective study designed to determine correlation between CCT and IOP. Records of 121 patients were included in the study. Inclusion criteria were: IOP higher than 22 mm H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Ophthalmology

سال: 2001

ISSN: 0007-1161

DOI: 10.1136/bjo.85.7.792