Cementless total hip arthroplasty in posttraumatic osteoarthritis hip
نویسندگان
چکیده
منابع مشابه
Kyon Cementless Total Hip Arthroplasty
My interest in cementless Total Hip Arthroplasty began in 1993 when I was introduced to the experimental PCA-Howmedica system while visiting Dave De Young at NCSU Veterinary College. After previous experience with cemented prostheses, I was looking for a commercially available cementless system to eliminate the complications I had encountered with cemented hips, mainly aseptic implant loosening...
متن کاملCementless femoral fixation in total hip arthroplasty.
Cementless femoral fixation by means of bone ingrowth has been successful in total hip arthroplasty in patients with sufficient bone quality. Consistent bone ingrowth and resultant long-term success involve many factors, including surgical technique, initial mechanical stability achieved at time of implantation, stem design and material, and implant surface. One potential method for achieving f...
متن کاملCementless Femoral Fixation in Total Hip Arthroplasty
In 1995, the NIH (National Institutes of Health) Consensus Development Panel on Total Hip Replacement supported the use of hybrid fixation with a cemented stem and a noncemented cup because of excellent long-term results. However, today, 60% to 90% of the approximately 200,000 total hip arthroplasties performed yearly in the United States involve both a cementless cup and a cementless stem. The...
متن کاملCotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum
BACKGROUND Cotyloplasty is a technique that involves making a perforation of the medial wall of a shallow acetabulum and then inserting an acetabular cup with the medial aspect of its dome beyond the Kohler line. The purpose of this study was to evaluate the results of cementless total hip arthroplasty (THA) using cotyloplasty with focusing on the amount of medial cup protrusion. METHODS Sixt...
متن کاملThe cementless Vektor stem used in total hip arthroplasty
The cementless Vektor hip prosthesis stem is made of a special titanium alloy (TiAI6Nb7), and has a three-dimensional conus and an optimal proximal anchoring property. The aim of this prospective study was to scrutinise the first clinical and radiographical experiences of this stem used in 206 total hip replacements. The mean age of the patients including 126 women and 80 men was 54.6 years (ra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Orthopaedics Sciences
سال: 2018
ISSN: 2395-1958,2395-1958
DOI: 10.22271/ortho.2018.v4.i4f.53