Cemented versus uncemented femoral components in the ring hip prosthesis
نویسندگان
چکیده
منابع مشابه
Cemented versus uncemented femoral components in the ring hip prosthesis.
A prospective, randomised and independently assessed trial of the Ring UPM total hip replacement showed that the quality of the early result was better if the femoral prosthesis was cemented than if it was not. More patients with cemented prostheses were painfree at four months (58% cemented:42% uncemented) and at one year (63% cemented:50% uncemented), but at two years pain relief was equal in...
متن کاملUncemented custom femoral components in hip arthroplasty
BACKGROUND AND PURPOSE We have developed an individually designed, uncemented femoral component for achievement of improved strain distribution and fixation to the bone, to make uncemented stems more applicable in femurs of abnormal size and shape, and to improve the joint mechanics. Here we describe the design of the implant and present the results of a prospective clinical study with at least...
متن کاملSurvivorship of the KUDO total elbow prosthesis— comparative study of cemented and uncemented ulnar components
متن کامل
Mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study
BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...
متن کاملMore complications with uncemented than cemented femoral stems in total hip replacement for displaced femoral neck fractures in the elderly
Background and purpose - Total hip replacement (THR) is the preferred method for the active and lucid elderly patient with a displaced femoral neck fracture (FNF). Controversy still exists regarding the use of cemented or uncemented stems in these patients. We compared the effectiveness and safety between a modern cemented, and a modern uncemented hydroxyapatite-coated femoral stem in patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Bone and Joint Surgery. British volume
سال: 1992
ISSN: 0301-620X,2044-5377
DOI: 10.1302/0301-620x.74b6.1447241