Cell-based refractometer for pascal realization
نویسندگان
چکیده
منابع مشابه
Pascal-Interpolation-Based Noninteger Delay Filter and Low-Complexity Realization
This paper proposes a new method for designing the polynomial-interpolation-type noninteger-delay filter with a new structure formulation. Since the design formulation and the new realization structure are based on the discrete Pascal transform (DPT) and Pascal interpolation, we call the resulting filter Pascal noninteger-delay filter. The kth-order Pascal polynomial is used to pass through the...
متن کاملA Semantically-based Formatting Discipline for Pascal
The abstract (or sem antic) syntax of the Pascal language is identi fied. and a linea r representation fo r the trees so formed within the framework of the concrete syntax fo r that language is imposed. The indentation schem e so form ed, augm ented with a sm all numDer of pragm atic considera tions, is com pared with several previously proposed formatting schem es for Pascal and an example of...
متن کاملA spectroscopic refractometer based on plasmonic interferometry
We describe the design, fabrication, and testing of a spectroscopic refractometer that employs plasmonic interferometry to measure the optical dielectric functions of materials in the visible range. The proposed device, dubbed a plasmonic refractometer, consists of an array of slit-groove plasmonic interferometers etched in a 300 nm-thick metal film (silver or gold) with arm lengths varying in ...
متن کاملLiquid refractometer based on immersion diffractometry.
This study presents a laser diffractometric refractometer for measuring the refractive index of liquids. The refractive index is determined by rotating a reflection grating that is immersed in the fluid under test, and measuring the first-order Littrow diffraction angle. The Littrow angle is easily detected form the interferogram formed by the diffracted beam from the grating and the reflected ...
متن کاملAn automatic interference refractometer.
Interference refractometry is a well-established method of determining the concentration of anaesthetic agents in gas mixtures. A photo-electric detector system has been fitted to a small portable, direct-reading interference refractometer to display automatically the concentration of the agent being measured. The design of the instrument is described and two possible methods of information dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Letters
سال: 2017
ISSN: 0146-9592,1539-4794
DOI: 10.1364/ol.42.002944