CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches
نویسندگان
چکیده
منابع مشابه
A Search of Low-Mass WIMPs with p-type Point Contact Germanium Detector in the CDEX-1 Experiment
W. Zhao, Q. Yue, ∗ K.J. Kang, J.P. Cheng, Y.J. Li, H.T. Wong, † S.T. Lin, 7, ‡ J.P. Chang, J.H. Chen, † Q.H. Chen, Y.H. Chen, Z. Deng, Q. Du, H. Gong, X.Q. Hao, H.J. He, Q.J. He, H.X. Huang, T.R. Huang, † H. Jiang, H.B. Li, † J. Li, J. Li, J.M. Li, X. Li, X.Y. Li, Y.L. Li, F.K. Lin, † S.K. Liu, L.C. Lü, H. Ma, J.L. Ma, S.J. Mao, J.Q. Qin, J. Ren, J. Ren, X.C. Ruan, V. Sharma, 8 M.B. Shen, L. Si...
متن کاملUltra-Low-Energy Germanium Detector for Neutrino-Nucleus Coherent Scattering and Dark Matter Searches
The status and plans of a research program on the development of ultra-low-energy germanium detectors with sub-keV sensitivities are reported. We survey the scientific goals which include the observation of neutrino-nucleus coherent scattering, the studies of neutrino magnetic moments, as well as the searches of WIMP dark matter. In particular, a threshold of 100-200 eV and a sub-keV background...
متن کاملSearch for an annual modulation in a p-type Point Contact germanium dark matter detector.
Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of weakly interacting massive particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistic...
متن کاملResults from a search for light-mass dark matter with a p-type point contact germanium detector.
We report on several features in the energy spectrum from an ultralow-noise germanium detector operated deep underground. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss an irreducible excess of bulklike events below 3 keV in ionization energy. These could be caused by unknown backgrounds, but also dark m...
متن کاملProspects of cold dark matter searches with an ultra-low-energy germanium detector
The report describes the research program on the development of ultra-low-energy germanium detectors, with emphasis on WIMP dark matter searches. A threshold of 100 eV is achieved with a 20 g detector array, providing a unique probe to the low-mas WIMP. Present data at a surface laboratory is expected to give rise to comparable sensitivities with the existing limits at the 5 − 10 GeV WIMP-mass ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chinese Physics C
سال: 2013
ISSN: 1674-1137
DOI: 10.1088/1674-1137/37/12/126002