Cavity Ring-Down Absorption Spectrography based on filament-generated supercontinuum light

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase shift cavity ring down absorption spectroscopy

Cavity ring down absorption spectroscopy with a continuous light souree is used to measure the transition frequencies and absolute absorption coefficient of the weak b ItCv' = 2) +--X I;-Cv" = 0) transition of 02. The absorption spectrum is extracted from a measurement of the magnitude of the phase shift that an intensity modulated continuous light beam experiences upon passing through an unsta...

متن کامل

Saturated-absorption cavity ring-down spectroscopy.

We report on a novel approach to cavity ring-down spectroscopy with the sample gas in saturated-absorption regime. This technique allows us to decouple and simultaneously retrieve the empty-cavity background and absorption signal, by means of a theoretical model that we developed and tested. The high sensitivity and frequency precision for spectroscopic applications are exploited to measure, fo...

متن کامل

Cavity ring-down spectroscopy for quantitative absorption measurements

We examine under what conditions cavity ring-down spectroscopy ~CRDS! can be used for quantitative diagnostics of molecular species. We show that CRDS is appropriate for diagnostics of species whose absorption features are wider than the spacing between longitudinal modes of the optical cavity. For these species, the absorption coefficient can be measured by CRDS without a knowledge of the puls...

متن کامل

Cavity ring-down spectrometer for high-fidelity molecular absorption measurements

We present a cavity ring-down spectrometer which was developed for near-infrared measurements of laser absorption by atmospheric greenhouse gases. This system has several important attributes that make it possible to conduct broad spectral surveys and to determine line-by-line parameters with wide dynamic range, and high spectral resolution, sensitivity and accuracy. We demonstrate a noise-equi...

متن کامل

Cavity Ring-down Biosensing

Cavity ring-down spectroscopy (CRDS) is an established technique for gases sensing that is newly emerging in the field of optical biosensing. This approach measures changes in the rate of decay of light injected into an optical resonator and relates them to optical loss along its length. This principle has recently been adapted for use in liquids, providing a highly sensitive method for quantit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2009

ISSN: 1094-4087

DOI: 10.1364/oe.17.003673