Causes of phakic implantable collamer lens explantation/exchange at king Khaled eye specialist hospital

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changing epidemiology of neovascular glaucoma from 2002 to 2012 at King Khaled Eye Specialist Hospital, Saudi Arabia

PURPOSE The aim is to present the incidence and determinants of neovascular glaucoma (NVG) in Saudi Arabia. METHODS A retrospective review of NVG cases (2002-2012) was included to estimate the incidence. The determinants included gender, age, comorbidities, lens status, type of NVG, and visual acuity on presentation. The impact of antiangiogenic therapy on NVG incidence was studied. RESULTS...

متن کامل

Implantable Collamer Lens Versus Iris-Fixed Phakic Intraocular Lens Implantation to Correct Myopia: A Meta-Analysis

This study is a meta-analysis comparing the efficacy, predictability, and safety of correcting myopia via implantation of two types of phakic intraocular lens (PIOLs): the implantable collamer lens (ICL) and iris-fixed PIOL. The Cochrane library, Pubmed, and EMBASE were searched. Study selection, data exclusion, and quality assessment were performed by two independent observers. The pooled rela...

متن کامل

Standardized analyses of correction of astigmatism with the visian toric phakic implantable collamer lens.

PURPOSE To demonstrate the methodology described by the American National Standards Institute (ANSI) Standard Subcommittee on Astigmatism Analysis reporting a standardized method of presenting astigmatism data by laser systems that reshape the cornea also applies to toric phakic intraocular lens (IOL) data. METHODS The U.S. Food and Drug Administration trial of the Visian Toric Implantable Co...

متن کامل

Posterior Vitreous Detachment and Retinal Detachment After Implantation of the Visian Phakic Implantable Collamer Lens

INTRODUCTION To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. MATERIALS AND METHODS This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May ...

متن کامل

Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes

PURPOSE The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism. METHODS Forty-three eyes of 23 patients underwent implantation of a toric implantable collamer lens (STAAR Surgical Inc) for astigmatism correction. Mean spherical refraction was -4. 98 ± 3.49 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Middle East African Journal of Ophthalmology

سال: 2016

ISSN: 0974-9233

DOI: 10.4103/0974-9233.194076